▪ Compact-design, single-axis digital readout, equipped with the new Absolute Warning System (AWS).
▪ AWS constantly guarantees the correctness of the displayed positions and informs the operator of any malfunctioning.
The user can continue machining or, based on the error message displayed, intervene to restore the proper functioning
of the system.
▪ Suitable for several machine tools, such as those performing cutting or machining at a preset size, polishing, bending,
grinding or straightening.
▪ Applicable on various industries, such as wood, sheet metal, marble, rubber, textile and automation.
▪ Absolute (SSI protocol) or incremental encoder input signals.
▪ Up to 8 digits displayed, including floating decimal point and negative sign.
▪ Device diagnostic.
▪ Internal rewritable memory.
▪ Absolute signals RS-422: Clock+, Clock-, Data+, Data-.
▪ Resolutions up to 0.5 μm.
▪ Correction factor, angular reading, programmable relay outputs and many other functions available.
▪ Serial output RS-232, for the transmission of positions.
▪ Panel mountable version available.
VI518 Standard version | |
Display | 8 high-efficiency digits h = 13 mm | |
Incremental encoder input signals | 2 square waves with phase displacement of 90° ± 5° and zero ref. 5 Vdc or 12 Vdc |
Power supply | 230 Vac ± 10% - 50/60 Hz 40 mA 110 Vac ± 10% - 60 Hz 80 mA 24 Vac ± 10% - 50/60 Hz 350 mA |
Memory | permanent for configuration and “user” settings (last data operating memory) |
Available resolutions | 200 - 100 - 50 - 20 - 10 - 5 - 2 - 1 - 0.5 μm 1° - 0.5° - 0.2° - 0.1° - 0.05° - 0.02° - 0.01° - 0.005° - 0.002° - 0.001° |
VI518 Version with options | |
Display | 8 high-efficiency digits h = 13 mm | |
Incremental encoder input signals | 2 square waves with phase displacement of 90° ± 5° and zero ref. 5 Vdc or 12 Vdc |
Absolute (SSI) encoder input signals | RS-422: Clock+, Clock-, Data+, Data- |
Power supply | 230 Vac ± 10% - 50/60 Hz 40 mA 110 Vac ± 10% - 60 Hz 80 mA 24 Vac ± 10% - 50/60 Hz 350 mA |
Memory | permanent for configuration and “user” settings (last data operating memory) |
Available resolutions | 200 - 100 - 50 - 20 - 10 - 5 - 2 - 1 - 0.5 μm 1° - 0.5° - 0.2° - 0.1° - 0.05° - 0.02° - 0.01° - 0.005° - 0.002° - 0.001° |
Options | serial output RS-232 relay outputs static relays AC - static relays DC absolute (SSI) encoder input |